Inhaltsverzeichnis

Seite 1 - 2007-6

1 KUZMA AIR LINE AIR BEARING TONEARM

Seite 2 - KUZMA LTD

10 4. Adjustment of tangential geometry Protractor Put a record on the platter and, using the cueing device lever, lower the cartridge on to t

Seite 3

11 Move the cartridge along the headshell to such a distance, that the tip of the diamond (needle) is on the line on the protractor, which

Seite 4

12 The tone arm is correctly levelled when: Above the outer grooves whole assembly should move slowly away from the record.

Seite 5 - Basic setup:

13 Of course the use of a test record and osciloscope is mandatory for optimal azimuth. VTA changes and even changes in the height

Seite 6

14 Damping system Damping change Release black plastic

Seite 7

15 Mainentance When air is consumed, the compressor works automatically, aproximately every minute and then rests for about a

Seite 8

16 Spread cloth over the platter under the blue bearing and from bottle, squeeze alcohol on to the inside of the bearing, which will then drain

Seite 9

17 Problems Cartridge skips the groove: Tonearm is not horizontal: check horizontality Excessive dirt on record: check and clean for small p

Seite 10

2 KUZMA LTD INSTRUCTION MANUAL FOR AIR LINE tonearm The Air line tonearm is a very precisely engineered p

Seite 11

3 General description: Main outer box contains two inner boxes. One box contains the compressor with oil and PVC drain bottle and the se

Seite 12

4 1. Unpacking: Compressor with drain bottle Compressor box: Open the box and lift up the compressor by the handle. It is a heavy item. Rem

Seite 13

5 Basic setup: Mount the armbase onto armboard. The dimension and position is the same as for Stogi ton

Seite 14

6 Compressor: for details see instructions with the compressor. The compressor has a safety valve and overheating protection!

Seite 15

7 filters. On one end of this longer part is a valve. This end should be connected to the red filters. The valve lever should be in »close position«

Seite 16

8 *Valve on drain tube: Optional by order. For normal operation this should be open (level along axis of tube). If used in the same room as tone a

Seite 17

1. Setting up the tonearm: Again check the height of the tonearm. The basic height should be such, that the centre of the shaft (centre of vertic